<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-27 12-24-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 70 kHz 10099 4,3470
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,0 dBr 7,68 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 12:24, 27.02.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (57 dBuV) Max at: 70 kHz MIN: 13 kHz % above 75 kHz: 4,3470 Acquired: 2025/02/27 12:23:09 Total samples: 10099 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,2 dBr MIN: 7,0 dBr AVE: 7,68 dBr % above 10,0 dBr: 0,0 Last value: 8,1 dBr (2025/02/27 12:23:08) Station: 96.90 MHz, signal: 5/5 (57 dBuV) 12:16 12:17 12:18 12:19 12:20 12:21 12:22 12:23 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality